transformers

greenspun.com : LUSENET : The Plumb Truth : One Thread

is it possible to use ONE transformer for one Toto urinal and one toilet with an electronic flush valves and an eagle eye chicago faucet in one bathroom, and another toilet and faucet in the other adjacent bathroom?

(total of five units with one transformer).

jorge

-- jorge marien (jorge@callas-shortridge.com), October 04, 2000

Answers

Jorge, It is possible to power up to 6 fixtures with one transformer but you must use a chicago#118 multiple power supply. Also depending on the distance traveled from the power source to the fixtures you must make sure you use the proper guage wire.The Chicago Eagle Eye faucets and the Toto flush valves are both 24vac, however note that the Chicago Eagle Eye-XT valves are rated at 6volts dc and could not be used in this situation,

-------------------------------------------- Randy Cisneros National Sales Manager Hirsch Pipe & Supply 6141-A Kester Ave. Van Nuys CA 91411 Phone:818-756-3550 ext 246 Fax:818-786-5165 Email:randyc@hirsch.com ----------------------------

-- RANDY CISNEROS (RANDYC@HIRSCH.COM), October 06, 2000.